– 30 –
(Continued next page)
Fault 
Code 
Fault Name  Description Repair Action
16 Adaptive Drain/Slow 
Drain
The total number of times during machine 
life that the actual amount of time the 
pressure sensor indicated the wash 
water had drained to empty exceeded the 
calculated time by the software.
 This fault is set when adaptive 
drain cycle occurs to try to 
remove the rest of water in tub.
 If the adaptive drain cycle times 
out, the control will run a Drain 
Pump Clearing algorithm to free 
the pump impeller of debris. 
7KHQLWZLOO¿QLVKGUDLQLQJ,I
drain clearing algorithm fails 
look for Fault 18.
 If Fault 16 is 100 and Fault 
18 never occurs there is no 
problem. If Fault 16 and Fault 
18 equal each other in faults, 
then look for drain blockages 
including house standpipe.
17 Dry Load Sense 
Timeout
Dry load sense times out and moves to the 
next part of the cycle selected. This occurs 
when the washer is not reaching the target 
VSHHGZLWKLQDGH¿QHGWLPHOLPLWIRUWKHORDG
type selected.
1.  Check for water in the bottom 
of the tub. If so, drain and try 
cycle again.
2.  Check the basket for excessive 
friction. Basket should spin 
IUHHO\,IQRW¿QGVRXUFHRI
friction and remove it.
18 Drain Pump Clearing 
 
algorithm failed.
While draining, the pressure sensor value 
for water level did not indicate the washer 
was empty before the Max Continuous 
Drain ON time was reached.
 This fault is set and will be seen 
with Fault 16 when Drain Pump 
Clearing Algorithm failed to 
remove the blockage and the 
rest of water in tub.
 Check the drain pump for 
blockage.
 Check installation instructions 
for proper standpipe height.
 Check pressure tube for 
pinches where it goes through 
top cover grommet.
 Check pressure tube for 
trapped water. 
 Check the output voltage from 
the pressure sensor to ensure 
it matches the water level in 
the basket according to the 
pressure sensor chart.
 Check resistance of the 
pump (13.5 ohms) from J512 
connector on the control.
 If open circuit, check wiring 
harness to the pump and pump 
motor.
 Check for 120 VAC to the drain 
pump.
 If voltage is present and pump 
does not operate, replace 
pump.
 If voltage is not present, 
replace IMC (Interface Machine 
Control).
19 UI State Time-out Washer was paused for over 12 hours.  This is normal operation. This 
will happen if the consumer and 
or control switched cycle to a 
paused state.