Bottom of Subwasher
Platform Assembly Removal
Remove the 1 and 5/16 inch hub
nut. The Torque when re-
installing the Hub Nut is 100 ft.
lbs.
First remove the impeller
held down by a 7/16
bolt. Lift the impeller up.
The coupler may come
off with the impeller. If
not, remove it also.
Top center of the impeller with
cap removed exposing the 7/16
bolt.
Torque Limiter tool is use with
impact gun to achieve the proper
torque.