Ice Maker continued
After the ice cubes harvest, the mold is pre-chilled to
35°F before starting the ll process. When the mold
temperature reaches 36°F, the ice maker will ll for 5.1
seconds. If the mold rises above 42°F, water reaches
the front of the mold and no further lls are needed.
If there is no change in the temperature then a 2.5
second ll will occur. If temperature does not rise a
third and nal time, a ll of 2.4 seconds will be initiated.
First Fill 5.1 sec.
Second Fill 2.5 sec.
Third Fill 2.4 sec.
Average cycle time, 75 - 90 minutes.
For more information about the Electronic Ice
Maker, refer to Technical Service Guide 31-9063.
Service Diagnostics for Electronic Ice Maker
During the rst 15 seconds that power is rst
applied to the icemaker, the Service Diagnostic Test
mode may be entered. The service mode is entered
by pushing the feeler arm from the “out” position to
the “in” position and back again 3 times (and only 3
times) within 15 seconds.