B-28 L30 Line Current Differential System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
3E4A ...Repeated for Field Shared Output 3
3E57 ...Repeated for Field Shared Output 4
3E64 ...Repeated for Field Shared Output 5
3E71 ...Repeated for Field Shared Output 6
3E7E ...Repeated for Field Shared Output 7
3E8B ...Repeated for Field Shared Output 8
3E98 ...Repeated for Field Shared Output 9
3EA5 ...Repeated for Field Shared Output 10
3EB2 ...Repeated for Field Shared Output 11
3EBF ...Repeated for Field Shared Output 12
3ECC ...Repeated for Field Shared Output 13
3ED9 ...Repeated for Field Shared Output 14
3EE6 ...Repeated for Field Shared Output 15
3EF3 ...Repeated for Field Shared Output 16
Field Unit RTDs (Read/Write Setting) (8 modules)
3F00 Field Unit RTD 1Name 0 to 1 --- 1 F205 "RTD 1"
3F06 Field Unit RTD 1 Origin 0 to 24 --- 1 F253 0 (None)
3F07 Field Unit RTD 1 Type 0 to 2 --- 1 F259 0 (100 Ohm
Nickel)
3F08 ...Repeated for Field Unit RTD 2
3F10 ...Repeated for Field Unit RTD 3
3F18 ...Repeated for Field Unit RTD 4
3F20 ...Repeated for Field Unit RTD 5
3F28 ...Repeated for Field Unit RTD 6
3F30 ...Repeated for Field Unit RTD 7
3F38 ...Repeated for Field Unit RTD 8
Field Unit Transducers (Read/Write Setting) (8 modules)
3F40 Field Unit Transducer 1 Name 0 to 1 --- 1 F205 "TRD 1"
3F46 Field Unit Transducer 1 Origin 0 to 24 --- 1 F253 0 (None)
3F47 Field Unit Transducer 1 Range 0 to 9 --- 1 F246 6 (0...20mA)
3F48 Field Unit Transducer 1 Min Value -9999.999 to 9999.999 --- 0.001 F004 0
3F4A Field Unit Transducer 1 Max Value -9999.999 to 9999.999 --- 0.001 F004 100000
3F4C Field Unit Transducer 1 Units --- --- --- F206 (none)
3F4F ...Repeated for Field Unit Transducer 2
3F5E ...Repeated for Field Unit Transducer 3
3F6D ...Repeated for Field Unit Transducer 4
3F7C ...Repeated for Field Unit Transducer 5
3F8B ...Repeated for Field Unit Transducer 6
3F9A ...Repeated for Field Unit Transducer 7
3FA9 ...Repeated for Field Unit Transducer 8
Field Unit Identifiers (Read Only) (8 modules)
3FB8 Attached Field Unit 1 Serial Number --- --- 1 F205 (none)
3FBE Attached Filed Unit 1 Port Number --- --- 1 F001 0
3FBF Attached Field Unit 1 Type 0 to 3 --- 1 F243 0 (CC-05)
3FC0 Field Unit 1 Status 0 to 4 --- 1 F262 0 (Disabled)
3FC1 ...Repeated for Field Unit 2
3FCA ...Repeated for Field Unit 3
3FD3 ...Repeated for Field Unit 4
3FDC ...Repeated for Field Unit 5
3FE5 ...Repeated for Field Unit 6
3FEE ...Repeated for Field Unit 7
3FF7 ...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000 Command Password Setting 0 to 4294967295 --- 1 F202 (none)
Table B–10: MODBUS MEMORY MAP (Sheet 20 of 63)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT