9–6 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
PORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUP
Example 9-2: Back pressure and flow control
ML2400#
device
ML2400(device)##
show flowcontrol
XOnLimit : 4
XOffLimit : 6
ML2400(device)## flowcontrol xonlimit=10 xofflimit=15
XOn Limit set successfully
XOff Limit set successfully
ML2400(device)## show flowcontrol
XOnLimit : 10
XOffLimit : 15
ML2400(device)## show backpressure
Rx Buffer Threshold : 28
(continued on next page)