CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDS
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 17–13
17.6 Ping
17.6.1 Ping through the Command Line Interface
The ping command can be used to test connectivity to other devices as well as checking
to see if the IP address is setup correctly. The command syntax is:
ping <ipaddress> [count=<1-999>]
[timeout=<1-256>]
For example:
ML2400# ping 3.94.248.61
3.94.248.61 is alive, count 1, time = 40ms
ML2400# ping 3.94.248.61 count=3
3.94.248.61 is alive, count 1, time = 20ms
3.94.248.61 is alive, count 2, time = 20ms
3.94.248.61 is alive, count 3, time = 40ms
ML2400#
Many devices do not respond to ping or block ping commands. Make sure that the target
device responds or the network allows the ping packets to propagate.
17.6.2 Ping through EnerVista Secure Web Management Software
The ping command can be used from EnerVista Secure Web Management Software to
test connectivity to other devices as well as checking to see if the IP address is correct.
Select the Administration > Ping menu item to use ping.
As mentioned earlier, many devices do not respond to
ping commands. Make sure that
the target device responds or the network allows ping packets to propagate.

Table of Contents

Other manuals for GE MULTILINK ML2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MULTILINK ML2400 and is the answer not in the manual?

GE MULTILINK ML2400 Specifications

General IconGeneral
BrandGE
ModelMULTILINK ML2400
CategorySwitch
LanguageEnglish

Related product manuals