CHAPTER 5: IP ADDRESSING IP ADDRESSING
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 5–7
Current Sessions:
SL# Sessn Id Connection User Name User Mode
1 1 163.10.10.14 manager Manager
2 2 163.11.11.1 peter Manager
3 3 163.12.12.16 operator Operator
ML2400#
kill session id=3
Session Terminated
ML2400#
In the above example, the user with username “peter” is given telnet access. Then multiple
users telnet into the switch. This is shown using the
show session command. The user
operator session is then terminated using the
kill session command.
Note
A maximum of four simultaneous telnet sessions are allowed at any time on the switch.
The commands in these telnet windows are executed in a round robin fashion; that is, if
one window takes a long time to finish a command, the other windows may encounter a
delay before the command is completed. For example, if one window is executing a file
download, the other windows will not be able to execute the command before the file
transfer is completed. As well, if a outbound telnet session is started from the switch
(through a telnet window) then other windows will not be able to execute a command until
the telnet session is completed.

Table of Contents

Other manuals for GE MULTILINK ML2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MULTILINK ML2400 and is the answer not in the manual?

GE MULTILINK ML2400 Specifications

General IconGeneral
BrandGE
ModelMULTILINK ML2400
CategorySwitch
LanguageEnglish

Related product manuals