CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUS
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 7–9
7.3 Configuring 802.1x with EnerVista Secure Web Management Software
7.3.1 Commands
To access the 802.1x configuration window, select the Configuration > Radius > Server
menu item.
First, select the server. Do not enable RADIUS capabilities until you have ensured that the
ports are configured properly. After the ports are configured, enable RADIUS. Also ensure
that the port connected to the RADIUS server, or the network where the RADIUS server is
connected to, is not an authenticated port.
The following window shows the configuration of a RADIUS Server. Initially, the RADIUS
Services are disabled and the server IP address is set to 0.0.0.0. Edit the server IP and
secret to add a RADIUS server.
The following figure illustrates the editing of information for the RADIUS server. Note the
UDP port number can be left blank and the default port 1812 is used.
After configuring the server information, specific port information is configured.

Table of Contents

Other manuals for GE MULTILINK ML2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MULTILINK ML2400 and is the answer not in the manual?

GE MULTILINK ML2400 Specifications

General IconGeneral
BrandGE
ModelMULTILINK ML2400
CategorySwitch
LanguageEnglish

Related product manuals