CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDS
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 17–3
Alarm relays (continued)
ML2400(alarm)##
add event=2
Alarm Event(s) Added: 2
ML2400(alarm)## show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId Description Mode
------------------------------------------
1 S-RING OPEN SUSTAINED
2 Cold Start MOMENTARY
3 Warm Start MOMENTARY
4 Link Up MOMENTARY
5 Link Down MOMENTARY
6 Authentication Failure MOMENTARY
7 RMON Raising Alarm MOMENTARY
8 RMON Falling Alarm MOMENTARY
9 Intruder Alarm MOMENTARY
10 Link Loss Learn Triggered MOMENTARY
11 Broadcast Storm Detected MOMENTARY
12 STP/RSTP Reconfigured MOMENTARY
ML2400(alarm)## alarm enable
Alarm system Enabled
ML2400(alarm)## show alarm
Alarm Events Configuration
--------------------------
Alarm Status: ENABLED
Relay Closure Time Period: 5 Seconds
EventId Description Mode
------------------------------------------
1 S-RING OPEN SUSTAINED
2 Cold Start MOMENTARY
3 Warm Start MOMENTARY
4 Link Up MOMENTARY
5 Link Down MOMENTARY
6 Authentication Failure MOMENTARY
7 RMON Raising Alarm MOMENTARY
8 RMON Falling Alarm MOMENTARY
9 Intruder Alarm MOMENTARY
10 Link Loss Learn Triggered MOMENTARY
11 Broadcast Storm Detected MOMENTARY
12 STP/RSTP Reconfigured MOMENTARY
ML2400(alarm)## alarm disable
Alarm system Disabled
ML2400(alarm)## del event=1,3,5,7
Alarm Event(s) Deleted: 1, 3, 5, 7
(continued on next page)