NX-4V2 Control 31
LOC PG DESCRIPTION DEFAULT PROGRAM DATA
L
42 19 GO TO PROGRAM CODE 9-7-1-3-0-0 _ _ _ _ _ _
43 19 GO TO PROGRAM CODE & AUTHORIZATION
Segment 1 (Circle numbers to program)
1 = Reserved.
2 = Enables "Go To Program Code" as an arm only code.
3 = Enables "Go To Program Code" as an arm only after closing.
4 = Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = Enables "Go To Program Code" as an arm/disarm code.
6 = Enables "Go To Program Code" to bypass zones.
7 = Enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2 Reserved
L
44 19 DURESS CODE 15-15-15-15-15-15 _ _ _ _ _ _
45 19 RESERVED
46 20 AUXILIARY OUTPUTS 1-2 SPECIAL TIMING
Segments (Aux Out) 1 2
1 = Aux output timed in minutes.
2 = Aux output to latch.
3 = Aux output to stop timing upon user code entry.
4 = Aux output to activate only between closing & opening time.
5 = Aux output to activate only between opening & closing time.
6 = Invert auxiliary output (0 Volts going to 12V when activated).
7 = Reserved
8 = Reserved
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
47 20 AUXILIARY OUTPUT #1, EVENT & TIME
Segment 1: Event number for output # 1 0=Burglary alarm
Segment 2: Timing for output # 1 10 seconds
48 20 AUXILIARY OUTPUT #2, EVENT & TIME
Segment 1: Event number for output # 2 1=Fire alarm
Segment 2: Timing for output # 2 10 seconds
49 - 50 RESERVED
L
51 20 AUTOTEST CONTROL
Seg 1: Program a "1" if the interval is hours, a
"0" if in days. Add a A2" to suppress the daily
test or a A3" to suppress the hourly test.
1
Seg 2: Program the autotest interval from 1-
255 days or hours.
24
Seg 3: Program the autotest report in 24-hour
time format.
2
Seg 4: Program the autotest report time,
minutes after the hour.
0
52 21 OPENING TIME
Seg 1: Hour of the opening time. 8
Seg 2: Minutes after the hour of opening time. 0
53 21 CLOSING TIME / AUTO ARMING TIME
Seg 1: Hour of closing time / auto arming time. 20
Seg 2: Minutes after hour of closing / auto
arming time.
0
54 21 DAYS OF THE WEEK SYSTEM IS OPEN
Segment 1: Sunday Monday Tuesday
Wednesday
Thursday Friday Saturday Reserved
1 2 3 4 5 6 7 8
55 21 DAYS OF THE WEEK "AUTO ARMING" WILL OCCUR
Segment 1: Sunday Monday Tuesday
Wednesday
Thursday Friday Saturday
Disable retry
timer
1 2 3 4 5 6 7 8
WWW.DIYALARMFORUM.COM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-4V2 and is the answer not in the manual?

GE NetworX NX-4V2 Specifications

General IconGeneral
BrandGE
ModelNetworX NX-4V2
CategoryControl Panel
LanguageEnglish

Related product manuals