L LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data)
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0] is the
number of minutes, and the [r] stores the data and moves to the next segment of this location.
Segment 1 Dynamic Battery Test duration in minutes (0-255 minutes). Factory default is 0 = no test.
Segment 2 AC Fail report delay in minutes 0-255 minutes. Factory default is 5.
Segment 3 Power Up Delay in seconds (0-60 seconds). Factory default is 60.
Segment 4 Siren Time in minutes (1-254 minutes). Factory default is 8.
Segment 5 Telephone Line Cut delay in seconds (0-255 seconds). Factory default is 0 = no TLM.
Segment 6 Cross Zone time in minutes (0-255 minutes). Factory default is 5.
Segment 7 Chime time in 50 mS (1/20th second) increments from 0-12 seconds (0 = follows zone 255
latched). Factory default is 3.
Segment 8 Dialer delay in seconds (15-255 seconds). Factory default is 30.
Segment 9 Fire Alarm Verification time in seconds (120-255 seconds). Factory default is 0 = no fire alarm
verification. NOTE: This feature is not approved for residential use in California
Segment 10 Listen-In time in seconds (0-255 seconds). Factory default is 0 = no Listen-In time.
Note for UL LISTED SYSTEMS: The "Listen-In" feature cannot be enabled. The "Dynamic Battery Test"
feature cannot exceed four (4) hours. The dial delay shall be set to -0-.
LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data)
Segment 1:
1 - On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To
Program Code" are 6 digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A
SIX-DIGIT CODE BEFORE EXITING PROGRAMMING.
2 - On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming
call for download) functions.
3 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 5)
4 - Enable Walk-Test Mode (Refer to feature definitions beginning on page 5)
5-8 Reserved.
L LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data)
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code
option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in
location 41, the last 2 segments (digits) will be ignored. With the NX-8 disarmed, the "Go To Program Code" can be
used to enter the Program Mode.
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection)
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the
user ID is 255. (This code may not be changed in the Run Mode.)
Segment 1: 1 - Reserved.
2 - On enables "Go To Program Code" as an arm only code.
3 - On enables "Go To Program Code" as an arm only after closing.
4 - On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 - On enables "Go To Program Code" as an arm/disarm code.
6 - On enables "Go To Program Code" to bypass zones.
7 - On enables "Go To Program Code" opening and closing reports.
8 - Reserved.
Segment 2: 1 - On enables the "Go To Program Code" for Partition #1.
2 - On enables the "Go To Program Code" for Partition #2.
3 - On enables the "Go To Program Code" for Partition #3.
4 - On enables the "Go To Program Code" for Partition #4.
5 - On enables the "Go To Program Code" for Partition #5.
6 - On enables the "Go To Program Code" for Partition #6.
7 - On enables the "Go To Program Code" for Partition #7.
8 - On enables the "Go To Program Code" for Partition #8.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.

Related product manuals