NX-8 Control
28
LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT
SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS.
LOCATION 56- RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 56 contains the event code for any zone "Restore" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit in place of the alarm event code. The zone ID will always be reported as the ones digit of
the zone number (i.e. 9 for zone 29). This location contains 8 segments. Any segment left as "0" will follow the
Segment 1 selection.
Segment 1: - Partition #1, "Restore Code".
Segment 2: - Partition #2, "Restore Code".
Segment 3: - Partition #3, "Restore Code".
Segment 4: - Partition #4, "Restore Code".
Segment 5: - Partition #5, "Restore Code".
Segment 6: - Partition #6, "Restore Code".
Segment 7: - Partition #7, "Restore Code".
Segment 8: - Partition #8, "Restore Code".
LOCATION 57 - BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 57 contains the event code for a zone "Bypass" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 29). This location contains 8 segments. Any segment left as "0" will follow the Segment 1 selection.
Segment 1 - Partition #1, "Bypass Code".
Segment 2 - Partition #2, "Bypass Code".
Segment 3 - Partition #3, "Bypass Code".
Segment 4 - Partition #4, "Bypass Code".
Segment 5 - Partition #5, "Bypass Code".
Segment 6 - Partition #6, "Bypass Code".
Segment 7 - Partition #7, "Bypass Code".
Segment 8 - Partition #8, "Bypass Code".
LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (8 segments, numerical data)
Location 58 contains the event code for a zone "Tamper" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the zone number (i.e. 9 for zone 29). Any
segment left as "0" will follow the Segment 1 selection.
Segment 1 - Partition #1, "Tamper Code".
Segment 2 - Partition #2, "Tamper Code".
Segment 3 - Partition #3, "Tamper Code".
Segment 4 - Partition #4, "Tamper Code".
Segment 5 - Partition #5, "Tamper Code".
Segment 6 - Partition #6, "Tamper Code".
Segment 7 - Partition #7, "Tamper Code".
Segment 8 - Partition #8, "Tamper Code".

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.

Related product manuals