NX-8 Control
42
LOC
PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
ZONES 25-32, PARTITION SELECTION (Segment 1=Zone 25 thru Segment 8=Zone 32)
Segments
1
2
3
4
5
6
7
8
32
22
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
33
22
ZONES 33-40, ZONE TYPES
6-6-6-6-6-6-6-6
_ _ _ _ _ _ _ _
ZONES 33-40, PARTITION SELECTION (Segment 1=Zone 33 thru Segment 8=Zone 40)
Segments
1
2
3
4
5
6
7
8
34
22
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
35
22
ZONES 41-48, ZONE TYPES
6-6-6-6-6-6-6-6
_ _ _ _ _ _ _ _
ZONES 41-48, PARTITION SELECTION (Segment 1=Zone 41 thru Segment 8=Zone 48)
Segments
1
2
3
4
5
6
7
8
36
22
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
SIREN AND SYSTEM SUPERVISION
Segment #1 (Circle numbers to program)
L
37
23
1
2
3
4
5
6
7
8
Siren sounds for telephone line cut while armed.
Siren sounds for telephone line cut while disarmed.
Siren blast at arming.
Siren blast at exit delay expiration.
Siren blast at closing kissoff.
Siren sounds during a cross zone verification time.
Siren sounds for a tamper.
Siren blast one time for keyswitch arming, two times for disarming.
Segment #2 (Circle numbers to program)
1
2
3
4
5
6
7
8
Convert siren driver to voltage out.
Siren sounds for expander trouble (required for U.L.).
Immediate Restore by zone.
Dynamic battery test performed upon arming.
Battery missing test performed every 12 seconds.
Manual bell test performed during [r]-[4] test function.
Manual communicator test performed during [r]-[4] test function.
Box tamper enabled.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.