EasyManuals Logo

GE NX-1308E - Caddx 8 Zone LED Keypad User Manual

GE NX-1308E - Caddx 8 Zone LED Keypad
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
NX-8 Control
45
LOC
PG
DESCRIPTION
DEFAULT
DATA
AUXILIARY OUTPUT #1, EVENT & TIME
Segment #1: Program the event number for output #1 here.
0=Burglary alarm
47
25
Segment #2: Program the timing for output #1 here .
10 seconds
AUXILIARY OUTPUT #2, EVENT & TIME
Segment #1: Program the event number for output #2 here.
1=Fire alarm
48
25
Segment #2: Program the timing for output #2 here .
10 seconds
AUXILIARY OUTPUT #3, EVENT & TIME
Segment #1: Program the event number for output #3 here.
2= 24 Hour Alarm
49
25
Segment #2: Program the timing for output #3 here .
10 seconds
AUXILIARY OUTPUT #4, EVENT & TIME
Segment #1: Program the event number for output #4 here.
21-Armed State
50
25
Segment #2: Program the timing for output #4 here .
0=Follow condition
AUTOTEST CONTROL
Segment #1:
Program a "1" if the interval is hours, a "0" if in
days. Add a A2" to suppress the daily test or a A3" to s
uppress the
hourly test.
0
Segment #2: Program the autotest interval from 1-
255 days or
hours.
24
Segment #3: Program the autotest report in 24 hour time format.
2
L
51
27
Segment #4:
Program the autotest report time, minutes after the
hour.
0
OPENING TIME
Segment #1: Program the hour of the opening time.
8
52
27
Segment #2: Program the minutes after the hour of the
opening time.
0
CLOSING TIME / AUTO ARMING TIME
Segment #1: Program the hour of the closing time / auto
arming time.
20
53
27
Segment #2: Program the minutes after hour of closing / auto
arming time.
0
DAYS OF THE WEEK EACH PARTITION IS OPEN
Segments
1
2
3
4
5
6
7
8
54
27
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Reserved
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DAYS OF THE WEEK "AUTO ARMING" WILL OCCUR IN PARTITIONS 1-8
Segments
1
2
3
4
5
6
7
8
55
27
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Reserved
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.

Related product manuals