Water Valve
The water valve is a 120 VAC, dual solenoid type,
and is accessed by placing the control panel in
the service position. It is inserted and retained in
a cutout in the rear of the backguard and held in
place by 2 hex-head screws. It is only available as a
complete assembly.
The water valve has a ow rate of 2.8 gallons
per minute on the cold side and 1.8 gallons hot
side.
If the pressure switch is not satis ed within 20
minutes, a ll error code will be recorded. If the
pressure switch has not opened in 45 minutes,
the main control will de-energize the water valve
and place the washer in pause mode.
Each solenoid coil has an approximate
resistance value of 1.1K Ω.
To remove the water valve:
Disconnect power.1.
Place the control panel in the service position. 2.
(See
Control Panel.)
Remove the ll hoses from the water valve.3.
Disconnect the white wire harness from the hot 4.
water (H) solenoid valve.
Disconnect the red wire harnesses from the cold 5.
water (C) solenoid valve.
Note: The ll funnel hose is dif cult to remove.
Remove the ll funnel hose. Squeeze the clamp 6.
and slide it back. Carefully break the hose loose
by inserting a small at-blade screwdriver under
the hose to break the seal.
Remove the two 1/4-in. hex-head screws that 7.
hold the valve to the cabinet.
Disconnect
Fill Funnel Hose
Clamp
Automatic Temperature Control (ATC)
The automatic temperature control (ATC) is a feature
that utilizes a thermistor to regulate the water ll
temperature.
The thermistor has a negative temperature
coef cient (as temperature increases, resistance
decreases).
The thermistor is located in the outlet of the ll
funnel and will measure 50K Ω at room temperature
(77°F / 25°C).
If the thermistor reads outside the expected range
(10K - 120K Ω ), the main control will default to the
following pre-programmed ll temperature settings:
Tap Cold = cold water valve only
Cold = cold water valve only
Cool = hot and cold water valves
Colors = hot and cold water valves
Warm = hot and cold water valves
Hot = hot water valve only
When both valves are energized, the internal ori ces
in the valves meter the ow to a 60% cold and 40%
hot ratio.
With the lid open, ATC will remain activated. The
temperature of the water entering the washer
with the lid open may vary greatly from customer
expectations due to the cycling of the ll valve
solenoids.
Extreme water temperatures at low pressure can
cause the ATC to use it’s maximum number of
activations and revert to a preset ll routine. The
main control will not allow the water valve to cycle
more than 25 times per ll.
Resistance can be measured at the wire harness
located on the control board location J5. Make sure to
unplug the connector to isolate the thermistor before
taking resistance readings.
To determine the temperature of the incoming
water, the main control measures the difference
between the voltage sent and the voltage returned
from the thermistor. The main control then makes
temperature adjustments accordingly.