– 41 –
Note: The mode shift coil connects to C7 connector on inverter/motor assembly. Unplug C7 connector and
check continuity. Mode shift coil resistance value is approximately 98Ω @ room temperature (77ºF).
Mode Shifter Coil Test
Tub should stop spinning 7 seconds after lid is lifted.
If the tub takes approximately 10 seconds to stop, check drive belt for wear.
If tub coasts to stop, brake resistor has failed and inverter/motor assembly must be replaced.
If the tub takes longer than 25 seconds to stop, the inverter will initiate a brake resistor error code. (See
Inverter/Motor Error Codes.)
Brake Test
The brake resistor is
permanently molded
into the underside of
the inverter cover.