57
in.xe
"Pump 1 doesn't work" step-by-step
98
Pump 1 does not work!
Check for an error condition
on keypad display. If there is
one, refer to the specific sec-
tion indicated by the error
condition.
Verify low level program-
ming configuration.
If “Pump 1” indicator does not appear, use a spare keypad
to verify if keypad is defective.
If it is, replace keypad.
If not, replace Spa Pack.
If “Pump 1” indicator appears when Key 1 button is pressed,
verify if pump works in either speed.
Verify if “Pump 1” indicator
appears on keypad display
when you press Key 1 button.