66
in.xe"Nothing seems to work" flow chart
For 240 VAC systems:
Do you read 240 VAC between
line 1 & line 2, 120 VAC between
line 1 & neutral, 120 VAC between
line 2 & neutral on the board?
For 120 VAC systems:
Do you read 120 VAC between
line 1 & neutral?
Is there a jumper cable connected
between line 2 & neutral?
yes
no
There is an electrical
wiring problem.
Call an electrician.
Verify if keypad is connected
correctly to Spa Pack.
Replace
transformer fuse
Replace Spa Pack
if there is still nothing
on keypad display.
If nothing seems to work, turn off the main breaker off and visually inspect power input cable, gently pull on it to make sure is
properly tighten. Then, follow this troubleshooting flow chart: