Page #68 background image
67
in.xe
Nothing seems to work!
Verify that all screws are
properly tighten on the
terminal block.
Turn power off and make
sure that all cables hold firmly
in the terminal block if you
pull on them.
On the terminal block,
measure voltage between
line 1 and line 2.
You should get 240 VAC.
Measure voltage between
line 1 and neutral.
You should get 120 VAC.
Measure voltage between
line 2 and neutral.
You should get 120 VAC.
If you do not get good
readings, this indicates an
electrical wiring problem.
Call an electrician!
For 120 VAC Systems
Measure voltage between
line 1 and neutral.
You should get 120 VAC.
If you do not get good
readings, this indicates an
electrical wiring problem.
Call an electrician!