STB function manual reactivation
When the STB temperature limiter has been triggers and fan deactivated, its operation must
unconditionally be restored in order to ensure the proper functioning of the G-406-P11 controller.
In order for the unit to be reactivated, proceed as follows:
Damage or breaking to the capillary tube means the leaks of the
temperature limiter filled with liquid, which leads to the G-406-
P11 misperformance.
Should such fault be found, the temperature limiter should be
disconnected from the G-406-P11 controller, dismantled and
replaced with the brand new one.
6. G-406-P11 HANDLING
Starting the unit
1. Connect the unit to the power supply network (insert the plug to the plug-in socket).
The display will show four horizontal dashes. All functions, in particular, the equipment
controlling the boiler operation, i.e. pump, fan and feeding screw, are deactivated.
The unit will ignore pressing all pushbuttons except for the
pushbutton.
2. Turn the controller on by pressing the pushbutton.
When this pushbutton is pressed, the controller enters the status of manual controlling of
the central heating system boiler and reads the most recent user-defined settings of the
boiler operation parameters (see item 6).
1. Unscrew the black protective nut
(1).
2. Press RESET pushbutton
(2) to unblock.
3. Apply and secure
protective nut (1).