G-406-P11 SERVICE MANUAL PAGE 7
PPUH „GECO” Sp. z o.o. Edition I RELEASE DATE 2006-10-06
Manual control
Following pressing the pushbutton, the controller enters the manual mode of central heating
system boiler control. All equipment connected to the controller is deactivated, and the display
shows the central heating system boiler water temperature, measured by means of the sensor.
This mode allows activating the following equipment, notably:
1. Fuel feeding screw.
Pressing the pushbutton causes the activation of the feeding screw connected to the
controller, as well as the illumination of the bottom control diode found on the
pushbutton. When the pushbutton is pressed again, the feeding screw is deactivated and the
control diode goes off.
2. The fan.
When the pushbutton is pressed, the fan connected to the controller is activated, and
the corresponding top control diode goes on. When the pushbutton is pressed again, the fan
is deactivated and the control diode goes off.
In this operation mode, the feeding screw and the fan may be activated and deactivated irrespective
of one another.
Pressing the pushbutton causes the controller to abandon the automatic operation mode
(heating and sustaining) and to enter the manual operation mode, involving the immediate stop of
the operation of the fan, feeding screw and pump.