ADV20 QS, V1.02 7
Italiano English
Terminal Explanations
Terminal Symbol Explanation of Terminal Function
R/L1, S/L2, T/L3
AC line input terminals (1-phase/3-phase)
U/T1, V/T2, W/T3
AC drive output terminals for connecting 3-phase induction motor
+, -
Connections for External Brake unit (BU-2/4-ADV20/50 series)
Earth connection, please comply with local regulations.
The specification for the control terminals
The position of the control terminals
RS-485
10VMI1 MI3 MI524V AVI
RA
RB
RC
MI2 MI4 MI6 DCM ACMAFM
Frame Torque Wire
A, B 5.1-8.1kgf-cm (4.4-7in-lbf) 16-24 AWG. (1.3-0.2mm
2
)
NOTE
Frame A: ADV20-1004-KXX-1M/2MF/4F, ADV20-1007-KXX-2MF/4F, ADV20-1015-KXX-4F
Frame B: ADV20-2007-KXX-1M, ADV20-2015-KXX-2MF, ADV20-2022-KXX-2MF/4F,
ADV20-2037-KXX-4F
Control Terminals Explanations
Terminal
Symbol
Terminal Function
Factory Settings (NPN mode)
ON: Connect to DCM
MI1 Forward-Stop command
ON: Run in MI1 direction
OFF: Stop according to Stop Method
MI2 Reverse-Stop command
ON: Run in MI2 direction
OFF: Stop according to Stop Method
MI3 Multi-function Input 3
MI4 Multi-function Input 4
MI5 Multi-function Input 5
MI6 Multi-function Input 6
Refer to Pr.04.05 to Pr.04.08 for programming the
Multi-function Inputs.
ON: the activation current is 5.5mA.
OFF: leakage current tolerance is 10
μ
A.