Page #57 background imageLoading...
Page #57 background image
5780415F_MSW_GFX4-IR_05-2019_ENG
261
b.st
R/W
Stability band
(hot runners alarm power function)
0.0 ...
.....100.0 % f.s.
0.0
262
b.pf
R/W
Alarm power band
(hot runners alarm power function)
0.0 ...100.0 %
0.0
260
pf.t
R/W
Delay time for alarm power activation
(hot runners)
0 ...999 sec
0
160
rL.1
R/W
Allocation of reference signal
0
See: Generic alarms –Table of reference signals
163
rL.2
R/W
Allocation of reference signal
1
166
rL.3
R/W
Allocation of reference signal
- OR Output
2
170
rL.4
R/W
Allocation of reference signal
- AND Output
35
171
rL.5
R/W
Allocation of reference signal
- OR Output
4
172
rL.6
R/W
Allocation of reference signal
- AND Output
160
The parameters for alarm power are:
The alarm is not activated if the control (Ctr) is ON/OFF type, during Selftuning and in Manual.
5 min.
PF.t
SP
SP + b.St
SP - b.St
Average power + b.PF
Alarm power
Average power
Power
ON
Average power - b.PF
Process
variable