Power
Process
variable
SP
SP S
t.a.
SoP
Controller in open loop
Controller in closed loop
SoF
Read state
63
bit
STATE OF SOFTSTART
OFF = Softstart in Stop
ON = Softstart in Start
R
147
SOF
R/W
Softstart time
0.0 ...500,0 min
0,0
263
SP.S
R/W
Softstart setpoint
(preheating of hot runners)
0
264
SO.P
R/W
Softstart power
(preheating of hot runners)
-100,00....
....100,0 %
0,0
SOFTSTART FOR PREHEATING
This function lets you deliver a settable power (So.P) for time (SoF), after which normal control is resumed by means
of PID control.
Activation is only at switch-on, with manual-automatic switching during Softstart (the time restarts from 0), and if the
process variable is below setpoint SP.S.
265
xot
R/W
Select hot runner functions
0
Table of hot runner functions
Fault action
Enable power if PV is Enable
hot runners not stabilized preheating softstart
0 FA.P
1 X Average power
2 FA.P
3 X FA.P
4 FA.P X
5 X Average power X
6 FA.P X
7 X FA.P X
+8 enable GS.2
FA.P – see alarm for probe in short or connection error (SBR-ERR)