EasyManua.ls Logo

gefran QE1008-W SET - 7. TECHNICAL DATA; 7.1. QE1008-W (Sensor)

gefran QE1008-W SET
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Subject to technical modications
7. TECHNICAL DATA
7.1. QE1008-W (Sensor)
Strain gauge type Foil (GF = 2.0)
Bridge resistance 350Ω
Measuring range ± 800με
Output signal for radio transmission IEEE 802.15.4
TM
Signal range 30...100m
Sensitivity tolerance ± 0.2%
Transverse sensitivity 0.9 ± 0.2 %
Accuracy < ± 0.5% FS
Linearity < ± 0.5% FS
Hysteresis < ± 0.5% FS
Repeatability < 0.2% FS
Supply voltage when charging 6.2VDC (max. 6.5VDC)
Power consumption when charging 325mA
Ambient temperature 5...65°C
Storage temperature 0...65°C
Overload capability unlimited
Type of protection IP40
Material: Housing Aluminium
Material: Cover Plastic
Weight 530g