PN# 37026500123 05/15/2009
22
FIG. 6-5 2 x 4 under center of door opening.
CONTACT REVERSE TEST
The force adjustments and limit switch settings
MUST BE COMPLETED before testing.
1. Testing.
Open garage door using Wall Control.
Place a 2" x 4" board (laid flat) under center
of garage door opening (FIG. 6-5).
Close door using Wall Control.
When door contacts board, the door must stop
(within 2 seconds) and reverse direction
returning to open position.
2. Adjustment.
If the door does not properly reverse.
Check to see if door has "close" limit
programmed. It should not have reached its
"close" limit before hitting board.
If the door STOPS but does not reverse,
decrease "CLOSE FORCE" control
setting slightly (turn it counter-clockwise).
Test again. Repeat as necessary until door
reverses upon contacting board.
CLOSE
1. Press and hold both of the "SET" buttons
( & ) together until the green indicator
light blinks (about 5 seconds).
2. All close and open travel limit settings are
erased. Then follow the steps above to
reprogram close and open travel limits.
NOTE: The opener will not close the door
automatically unless the Safe-T-Beam
®
System is
installed.
SET
SET
ERASE - OPEN/CLOSE TRAVEL LIMIT

Other manuals for Genie 2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genie 2024 and is the answer not in the manual?

Genie 2024 Specifications

General IconGeneral
ConnectivityWi-Fi, Bluetooth
Battery BackupYes
Motor TypeDC
TypeGarage Door Opener
Smartphone ControlYes
Drive TypeBelt
Speed7 inches per second
Remote ControlYes
Motor Power1.25 HP
WarrantyLimited lifetime on motor, 5 years on parts, 1 year on accessories

Related product manuals