Monitored Reversing Devices
ODC Safe-T-Beams® (OPTIONAL)
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SCROLL (up or down) until display reads “ODC STB>ON” or
“ODC STB>OFF”
Figure
16.
3) Press SET/CLEAR
key
to
toggle between ON and OFF.
4) Press SCROLL (up or down)
to shift to a new function and lock setting.
5) Press CAL/RUN to return to run mode.
WARNING: Photocell systems provide entrapment protection when
mounted near the doorway in such a way that the lower portion of an
individuals leg will break the photocell beam during normal walking
through the doorway.
OPEN
L E
CAL
RUN
C LL
S T
SET
CLEAR
SCROLL
LOSE
CAL
RUN
S
C OLL
CLEAR
SCROLL
LEA
6.6
NOTE: Installation of Series II Safe-T-Beam® or Residential Safe-T-Beam® Monitored
Photocells DOES NOT make this unit legal for residential use. The Genie®
Company strictly prohibits any installation of a commercial unit in any
residentially zoned construction.
www.geniecompany.com 06-12
Standard Duty Operator
GCL-T
Current UL Approved Monitored Reversing Devices:
1) MillerEdge ME and MT series monitored edge sensors used in
combination with Timer-Close Module P/N OPABTCX.S.
2) MillerEdge ME and MT series monitored edge sensors used in
combination with MillerEdge Signature Module SM-101. (Direct
connect through STB inputs).
5) NEMA4 Monitored Photocells P/N OPAKPEN4GX.S.
3) Residential Safe-T-Beam® Monitored Photocells from The Genie® Company,
model OSTB-BX (P/N 38176R.S).
4) Series II Safe-T-Beam® Monitored Photocells (P/N OPAKPE.S).