EZiSYSTEM, How to Use the Sonde 65
3. Depth indication (refer to Sonde Depth in How to Use the Locator section)
Depth indication can be used with a suitable depth locator. The locator must be posi-
tioned directly over the Sonde and in line with it (rotate the locator on its axis to find
the highest reading). Press and hold the i Button for 2 seconds. The depth of the Sonde
will be displayed in the depth readout window and the Sonde mode icon will be visible
beneath the display.
For ease and convenience mark the ground every 3 to 4 metres.
For ease of use practice the process above ground
Tracing a "walk through"
sewer
If a “walk through” sewer is being
traced, another method is to place the
Sonde vertically, for example to
pinpoint a buried manhole. The
Locator will pick up a pool of signal
with a null point at the centre. This is
an accurate method, but it is essential
to ensure the Sonde is vertical.