EasyManua.ls Logo

Gesipa TAUREX 1 Axial - User Manual

Gesipa TAUREX 1 Axial
160 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TAUREX 1-4 Axial
Pneumatisch-hydraulisches
Blindniet-Setzgerät
Betriebsanleitung
Hydropneumatic
blind rivet setting tool
Operating instructions
Outil oléopneumatique pour
pose de rivets aveugles
Mode d‘emploi
Remachadora neumática
Instrucciones de uso
Rivettatrice pneumo-idraulica
Istruzioni per l‘uso
Pneumatisch-hydraulisch
blindklinkpistool
Gebruiksaanwijzing
Πνευματική-υδραυλική συσκευή
τοποθέτησης τυφλών πριτσινιών
Οδηγίες χρήσης
Pneumatikus-hidraulikus szegecshúzó
szerszám
Használati utasítás
Nitownica pneumatyczno-hydrauliczna
do nitów jednostronnie zamykanych
Instrukcja obsługi
气动液压式抽芯铆钉枪
操作说明书
Пневмогидравлический заклепочник для
установки вытяжных заклепок
Инструкция по обслуживания
Pneumatisk hydraulisk
blindnitte-apparat
Driftsvejledning
Pneumatisk-hydraulisk blindnitpistol
Bruksanvisning
Pneumaattis-hydraulinen vetoniittityökalu
Bruksanvisning
Pneumatisk hydraulisk blindnagleapparat
Käyttöohje
Rebitadeira pneumática-
hidráulica para rebites cegos
Manual de instruções
Pneumaticko-hydraulické
nýtovací nářadí pro trhací nýty
Návod k použití
GESIPA Blindniettechnik GmbH
Nordendstraße 13-39
64546 Mörfelden-Walldorf
Germany
T +49 (0) 6105 962 0
F +49 (0) 6105 962 287
info@gesipa.com
www.gesipa.com

Table of Contents

Questions and Answers

  • M
    matthew84Aug 9, 2025
    What to do if spent mandrel is not evacuated from Gesipa TAUREX 1 Axial?
    • M
      Michael WalkerAug 9, 2025
      If the spent mandrel is not evacuated, several factors could be at play. First, check if the spent mandrel container is full and empty it if necessary. Also, inspect the mandrel evacuation hose for blockages and clear them. Ensure that you are using the correct nosepiece; replace it according to the table if it's wrong. A worn nosepiece can also cause this issue, so replace it if needed. Lastly, a spent mandrel jammed in the jaws can be the culprit; clean the jaws and jaw housing, oil the sliding surfaces, and replace the jaws if they are worn.
  • M
    Michael GainesAug 25, 2025
    How to fix Gesipa TAUREX 1 Axial when blind rivet is not set?
    • J
      Joseph DuncanAug 25, 2025
      If the blind rivet is not set, several issues could be the cause. Start by cleaning and oiling the sliding surfaces of the jaws. If the jaws are worn, replace them. Verify that the working pressure is sufficient. If the tool stroke is too low, top up with hydraulic oil.