EasyManua.ls Logo

Gesipa AccuBird Pro - User Manual

Gesipa AccuBird Pro
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AccuBird
®
Pro
PowerBird
®
Pro GE/iBird
®
Pro
Elektro-mechanisches
Blindniet-Setzgerät
Betriebsanleitung
Battery Powered
Riveting Tool
Operating Manual
Riveteuse
électro-mécanique
Mode d’emploi
Remachadora eléctrica
Instrucciones de manejo
Rivettatrice elettrica a batteria
Manuale per l’uso
Elektro mechanisch
blindklinkpistool
Bedienings- en onderhouds
handleiding
Ηλεκτρομηχανική συσκευή πριτσινώματος
τυφλών πριτσινιών
Οδηγίες χρήσης
Elektro-mechanikus szegecshúzó készülék
Üzemeltetési utasítás
Nitownica akumulatorowa
Instrukcja obsługi
电动拉铆枪
操作说明书及备件目录
Электромеханический заклепочник
Инструкция по эксплуатации
Elektro-mekanisk
blindnitteapparat
Betjeningsvejledning
Elektro-mekanisk blindnitpistol
Bruksanvisning
Sähkömekaaninen
sokkoniittauslaite
Käyttöohje
Elektro mekaniskblindnaglepistol
Bruksanvisning
Equipamento eletromecânico
de rebitagem cega
Instrução de serviço
Elektro-mechanicky
nytovaci prˇistroj
Návod k obsluze
SFS Group Germany GmbH
Division Riveting – GESIPA
®
Nordendstraße 13-39
64546 Mörfelden-Walldorf
Germany
T +49 (0) 6105 962 0
F +49 (0) 6105 962 287
info@gesipa.com
www.gesipa.com

Other manuals for Gesipa AccuBird Pro

Questions and Answers

  • M
    martinrobertAug 14, 2025
    What to do if my Gesipa AccuBird Pro have no spent mandrel discharge?
    • C
      Christopher ConnerAug 14, 2025
      If your Gesipa Rivet Tool isn't discharging spent mandrels, several factors could be at play. First, the nosepiece might be too small; exchange it according to the table. Second, there might be dirt inside the head, so cleaning it is essential. Third, the spent mandrel container might be full, requiring you to take it off and empty it. Lastly, the mandrel tube could be blocked; remove the blocked mandrel and check for free ejection.
  • A
    Angela WangAug 17, 2025
    Why my Gesipa AccuBird Pro cannot set blind rivet?
    • D
      David CobbAug 17, 2025
      If your Gesipa Rivet Tool is unable to set blind rivets, the following reasons may apply: * The battery may be depleted. Charge or replace the battery if necessary. * The jaws may be dirty or worn. Clean and lubricate or grease the sliding surfaces, or replace them. * The jaw assembly may be loose. Tighten the jaw assembly.
  • A
    Amy PatrickAug 21, 2025
    How to fix Gesipa Rivet Tools blocked on return?
    • L
      Laura BrownAug 21, 2025
      If your Gesipa Rivet Tool is blocked on return, unscrew the steel head sleeve and remove the blockage.
  • R
    Roger HeathAug 25, 2025
    What to do if Gesipa Tools blind rivet cannot be set?
    • J
      Julie EllisonAug 26, 2025
      If a blind rivet cannot be set using Gesipa Tools, it may be due to several reasons. First, check the battery charge and replace it if necessary. Second, the jaws might be dirty or worn. In this case, clean and lubricate or grease the sliding surfaces, or replace the jaws. Third, the jaw assembly could be loose, so tighten it.
  • C
    Christina HuffmanAug 28, 2025
    Why are the LED lights flashing on my Gesipa Tools?
    • J
      Julia GrossAug 28, 2025
      If the LED lights are flashing on your Gesipa Tools, it could indicate a few issues. One potential cause is a low battery, so try changing the battery. Another reason could be that the blind riveting tool is overloaded. If the LED flashes slowly (1 Hz), select rivet dimensions according to work capacity. Alternatively, the tool might be blocked on return, indicated by the LED flashing fast (2 Hz). If this happens, unscrew the steel head sleeve and remove the blockage.
  • R
    Rebecca HoffmanSep 1, 2025
    What to do if there is no spent mandrel discharge from Gesipa Tools?
    • B
      brian11Sep 2, 2025
      If there is no spent mandrel discharge from Gesipa Tools, consider the following possibilities: * The nosepiece may be too small, so exchange it according to the table. * There might be dirt inside the head, so clean it. * The spent mandrel container could be full; take it off and empty it. * The mandrel tube might be blocked; remove the blocked mandrel and check for free ejection.
  • S
    Samuel RodriguezSep 5, 2025
    Why is my Gesipa Power Tool not setting blind rivets?
    • R
      Richard VillarrealSep 5, 2025
      If your Gesipa Power Tool is not setting blind rivets, the possible causes include a depleted battery (charge or replace it), dirty or worn jaws (clean and lubricate, or replace them), or a loose jaw assembly (tighten it).
  • U
    udominguezSep 9, 2025
    What to do if my Gesipa Power Tool has no spent mandrel discharge?
    • M
      Michael SimmonsSep 9, 2025
      If your Gesipa Power Tool isn't discharging spent mandrels, consider these potential issues: the nosepiece may be too small (exchange it according to the table), there could be dirt inside the head (clean it), the spent mandrel container might be full (empty it), or the mandrel tube could be blocked (remove the blocked mandrel and check for free ejection).

Summary

1. Blind rivet setting tool

1.1 Work capacity

Details the range of rivet sizes and materials supported by the tools.

1.2 Equipment;accessories

Lists included accessories and optional equipment for the tools.

1.3 Technical data

Provides key technical specifications like weight, stroke, and noise emission.

1.4 Nosepiece table

Details nosepiece selection based on rivet diameter and material.

1.5 Safety instructions

Outlines essential safety rules for operating the blind riveting tool.

1.6 Starting procedure

Step-by-step guide on how to prepare and start using the tool.

1.6.1 To attach spent mandrel container

Instructions for attaching the spent mandrel container.

1.7 Mode of operation

Explains the different operating modes of the blind riveting tool.

1.8 Lighting

Describes the LED lighting system and its settings.

1.9 Maintenance

Details the maintenance procedures for the blind riveting tool.

1.10 Storage

Provides guidance on proper storage of the tool.

1.11 Repairs

Information on how to handle repairs and warranty service.

2. Troubleshooting

2.1 Blind rivet cannot be set

Diagnoses and remedies for when a blind rivet cannot be set.

2.2 No spent mandrel discharge

Troubleshooting steps for issues with spent mandrel ejection.

2.3 LED lights flashing

Interprets LED flashing patterns for fault diagnosis.