EasyManua.ls Logo

Gesipa AccuBird Pro - Lighting; Maintenance

Gesipa AccuBird Pro
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
GB
— Continuous light/torch function:
The lighting is switched on after a riveting sequence and stays on for
approx. 10 minutes. The LEDs then turn o󰀨 automatically.
Zero position:
Lights switched o󰀨.
-- Work light:
Lights are switched on at the start of the riveting sequence. The LEDs stay
on for about 10 seconds and then switch o󰀨 automatically.
The blind riveting tool is equipped with 3 LED lights to illuminate the work space. These can
be turned on by turning the black ring (F) behind the LEDs. There are 3 settings, which are
displayed by an arrow cast in the housing.
1.8 Lighting
1.9 Maintenance
The maintenance of the blind riveting tool is limited to the complete claw mechanism and the
associated wearing parts:
Remove battery from the blind riveting tool.
Unscrew the head (B) using at wrench SW 14 or SW 24 and clean. Look for deposits in
the top of the head!
Unscrew the jaw housing (C) using 2 SW 17 at wrenches.
Take out the jaws (D), jaw pusher (E) and spring (F), clean them and lubricate or grease
the sliding surfaces; replace the jaws (D) if worn (blunt teeth!).
Re-assemble in reverse order ensuring that all parts are tightened! We recommend that
you secure the screw connection using a thread adhesive (such as Loctite 222 or Loctite
243).
The blind riveting tool is tted with an acoustic warning device, which provides information
about the remaining battery time. Beeps sound to tell the user when to change the battery.
This ensures that the blind riveting tool will not switch o󰀨 during a riveting operation.
3 beeps and ashing LED lights for 10 seconds:
The battery needs to be changed soon (about 20% battery charge remaining).
6 beeps and ashing LED lights for 10 seconds after every setting sequence: Change
the battery after a few more riveting sequences in order to guarantee safe riveting sequences
(approx. 10% battery remaining).
9 beeps and ashing LED lights for 10 seconds: The next riveting sequence cannot be
reliably carried out. The blind riveting tool is switched o󰀨. Change the battery.