2. Troubleshooting
2.1 Blind rivet cannot be set
Cause Remedy
No battery Charge battery; replace if necessary
Jaws dirty or worn Clean them and lubricate or grease the sliding surfaces
or replace them (see 1.9)
Jaw assembly loose Tighten (see 1.9)
2.2 No spent mandrel discharge
Cause Remedy
Nosepiece too small Exchange according to table (see 1.4)
Dirt inside head Clean (see 1.9)
Spent mandrel container full Take o󰀨 and empty
Mandrel tube blocked Remove blocked mandrel and check for free ejection (see 1.9)
2.3 LED lights ashing
Cause Remedy
No battery Change battery (see 1.7)
Blind riveting tool overloaded (LED ashes
slowly – 1 Hz)
Select rivet dimensions according to work
capacity (see 1.1; 1.7)
Blind riveting tool blocked on return (LED
ashes fast – 2 Hz)
Unscrew steel head sleeve and remove
blockage (see 1.9)
3. Warranty
The applicable terms and conditions of warranty shall apply and can be viewed under follow-
ing link: www.gesipa.com/agb