GHL Doser Resource Guide
Release 07/2018
28
(PL-0077) Level-Sensor, Floater or (PL-0082) Level-Sensor, Optical
(PL-0081) PL-LY Level sensor splitter
One sensor should be at the surface of the water and the second should be
submerged. This will define minimum and maximum water level for the water
change.
NOTE: Index refers to the Control Circuit used. If you use Control Circuit 1, use Index “1”.
To program the GHL Doser SA for AWC, please do the following:
1. Go to “Dose Overview” and select the first doser pump you wish to use for AWC.
2. Change this pump setting to “Level Control”, set
Index
to “1”, and
Function
to “Fill
Water”
3. Go to the next doser pump you wish to use and change this pump setting to “Level
Control”, set
Index
to “1”, and
Function
to “Drain Water”.
4. Go to “Timer” settings and select “Event Start” in the
switchmode
box.
5. Select the days of the week you want this timer to run.