WindSonic Doc No 1405 PS 0019 Issue 28 November 2019
67
Name
Command
Gill Output
U and V values from the
averaged vector (UV) data.
Scalar magnitude maximum
and direction associated with
that maximum converted
into U and V components
with CRC
ARC3!
a<U_vectorav><V_vectorav><U_from_scalarmax><
V_from_scalarmax><status><checksum><CR><LF>
e.g.
0+000.00+000.02+000.07+000.10+00JMJ<CR><LF>
Scalar average direction and
magnitude
AR4!
a<dir_scalarav><mag_scalarav><dir_at_mag_scalarm
ax><mag_scalarmax><status><CR><LF>
e.g. 0+062+000.04+123+000.12+00<CR><LF>
Scalar average direction and
magnitude with CRC
ARC4!
a<dir_scalarav><mag_scalarav><dir_at_mag_scalarm
ax><mag_scalarmax><status><checksum><CR><LF
>
e.g. 0+070+000.03+123+000.12+00JFr<CR><LF>
Scalar average direction and
magnitude, then converted
into U and V components.
AR5!
a<U_from_scalarav><V_from_scalarav><U_from_sc
alarmax><V_from_scalarmax><status><CR><LF>
e.g. 0-000.01+000.03+000.07+000.10+00<CR><LF>
Scalar average direction and
magnitude, then converted
into U and V components
with CRC.
ARC5!
a<U_from_scalarav><V_from_scalarav><U_from_sc
alarmax><V_from_scalarmax><status><checksum><
CR><LF>
e.g.
0+000.00+000.03+000.07+000.10+00E|[<CR><LF>
Start Measurement (Polar)
aM!
atttn<CR><LF> e.g. a0003
Send Data
aD0!
a<dir><mag><status><CR><LF>
e.g. 0+083+000.02+00<CR><LF>
Start Measurement (UV)
aM1!
atttn<CR><LF> e.g. a0003
Send Data
aD0!
a<U><V><status><CR><LF>
e.g. 0+000.00+000.02+00<CR><LF>
Start Measurement with
CRC (Polar)
aMC!
atttn<CR><LF> e.g. a0003
Send Data
aD0!
a<dir><mag><status><CRC><CR><LF>
e.g. 0+295+000.01+00B{T<CR><LF>
Start Measurement with
CRC (UV)
aMC1!
atttn<CR><LF> e.g. a0003
Send Data
aD0!
a<U><V><status><CRC><CR><LF>
e.g. 0+000.00+000.00+00JZY<CR><LF>
Acknowledge Active
a!
a<CR>< LF> e.g. 0<CR><LF>
Send Identification
aI!
a13GillInst 2487 B06 <sn><CR><LF>
e.g. 013GillInst 2487B0611220012<CR><LF>
Change Address
aAb!
b<CR><LF> e.g. 1<CR><LF>
Address Query
?!
a<CR><LF> e.g. 0<CR><LF>
Measurement on demand
aXLPM!
0LP<CR><LF>
Continuous Reading
aXHPM!
0HP<CR><LF>