4.5 Program Door Travel Limits
Setting your door travel limits is a vital part of the initial setup of your Gliderol opener. This
communicates to the opener the specific distance it must travel to complete an open/close cycle.
Item Description Display
4.5.1 Starting with the door in the closed position, press and hold the ‘SET’
button until ‘P1’ is visible on the display.
4.5.2 Press ‘SET’ and ‘OP’ (Open) will appear on the display.
4.5.3 Press and hold the ‘UP’ button until the door travels to the desired open
position.
4.5.4 Once the door has reached the desired open position, press ‘SET’ to save
in the units memory and ‘CL’ (Close) will show on the display.
4.5.5 Press and hold the ‘DOWN’ button until the door reaches the desired
closed position.
4.5.6 Once the door has reached the desired closed position, press ‘SET’ to
save in the units memory.
Once limits are set the unit will automatically perform a full calibration cycle during which the
door will open and close and automatically. When the door is closed after calibration, limit setup is
complete.
4.6 Program Force Settings
To ensure your doors Force Settings are correct, place a 40mm solid immovable object (eg block of
wood) in the middle of the opening and lower the door. The door should automatically reverse when
it touches the wood without further adjustments. If the door doesn’t auto-reverse, complete the
following steps to adjust settings:
Item Description Display
4.6.1 Press ‘SET’ until ‘P1’ is visible on the display.
4.6.2 Press the ‘UP’ button once and ‘P2’ will be visible on the display. Press ‘SET’
to confirm selection.
4.6.3 The Force Settings will now be shown on the display. Use the ‘UP’ and
‘DOWN’ buttons to increase/decrease the Openers force by one degree.
Note: Default setting is ‘F5’ (to suit most doors)
Maximum is ‘F9’ (to suit largest door)
Minimum is ‘F1’ (to suit smallest door)
4.6.4 Press the ‘SET’ button to save selection in the units memory.
(example)