Battery
J0
The power capacity
for sending out
battery low alarm
report
u8,
percent
15 ~ 100
J1
The power capacity
for power off TR-206
u8,
percent
10 ~ 100
J6
Battery low alarm
report Media
Media
type
bit0=SMS
bit1=TCP
bit2=UDP
bit5=USB
bit6=Action[0]
bit7=Action[1]
Action=00: report format 0
Action=01: report format 1
Action=10: GPS on
J7
The power capacity
for clear battery low
alarm flag
u8,
percent
10 ~ 100
J8
Enable/disable TR-
206 to
automatically power
on when power
capacity is charged
to the capacity of J1
1/0
0=disable
1=enable
Data logger
O2
Data logger interval
u16, in
seconds
1 ~ 65535
Default=60
OH
Data logger distance
u32, in
meters
0 ~ 4 Giga
0=disable
Other setting
O1
Motion sensor
sensitivity
u16
0 ~ 100
Default=5
O3
Report format 0
char(32)
Default=SORPZAB27GHKLMN*U!
ON
Report format 1
char(32)
Default=SPAN*U!
OG
Enable/ disable data
buffer function
1/0
Default=1