26ST100 User Manual v1 Confidential & Proprietary Information
8545-0194-01 v1.0
4.1.1.31. “sgactskip”
Bypass or reinstate the activation algorithm of ST100. Mostly used for line powered devices.
Command: sgactskip
Arguments: Set/Get flag: “0” gets the current skip activation state
“1” sets the current skip activation state
Skip activation state: Only valid when set/get flags is set to “1”
Example1: sgactskip 0
Example1 response: Current skip activation state: 0
Example2: sgactskip 1 1
Example2 response: Wrote skip activation flag to flash
4.1.1.32. “sgadprfx”
Set or get the BLE advertising prefix of ST100.
Command: sgadprfx
Arguments: Set/Get flag: “0” gets the prefix and “1” sets the prefix Advertising
Prefix: Only valid when the set/get flag is set to “1”
Example1: sgadprfx 0
Example1 response: Adv prefix: gst
Example2: sgadprfx 1 gst
Example2 response: Wrote adv prefix
NOTE: The advertising prefix must be of 3 bytes length. If it is not 3, then “Length error argv[2]” will be returned.
4.1.1.33. “sgbattemp”
Set or Get battery temperature configuration values.
Command: sgbattemp
Arguments: Set/Get flag: “0” gets the battery temperature config parameters
“1” sets the Battery temperature config parameters
Charging temp low: Only valid when Set/Get flag is set to “1”.
Low threshold for charging temperature. Min Value
Charging temp high: Only valid when Set/Get flag is set to “1”.
High threshold for charging temperature
Discharging temp low: Only valid when Set/Get flag is set to “1”.
Low threshold for discharging temperature.
Discharging temp high: Only valid when Set/Get flag is set to 1”.
High threshold for discharging temperature