28ST100 User Manual v1 Confidential & Proprietary Information
8545-0194-01 v1.0
4.1.1.35. “sghltint”
Health Check read or set message interval.
Command: sghltint
Arguments: Set/Get flag: “0” gets the current interval
“1” sets the interval
Interval: Number of days between messages, integer between 1 and 30
Example1: sghltint 0
Example1 response: Health check interval: %u, Next time to transmit: %u
Example2: sghltint 1 25
Example2 response: Successfully set the health check interval
4.1.1.36. “sglogpar”
Lists the current logging parameters.
Command: sglogpar
Arguments: Set/Get flag: “0” gets the logging parameters
“1” sets the logging parameters
Logging Mode: Only valid when set/get flag is set to “1”.
Possible logging modes: 0 -> reduced mode
1-> basic mode
2-> verbose mode
Logging Overflow: Only valid when set/get flag is set to “1”.
Possible overflow modes: 0 -> Overflow disabled
1-> Overflow enabled
Example1: sglogpar 0
Example1 response: Logging Mode: 1
Logging Overflow status: 1
Example2: sglogpar 1 1 1
Example2 response: Logging Mode: 1
Logging Overflow status: 1
Wrote logging parameters to flash (When set/get flag is set to “1”)