C Overview of diagnostics codes
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Dia-
gnostics
code
Parameter
Values
Unit Increment, select, explanation
Default set-
ting
Own setting
Min. Max.
d.00 Heating maximum
output
kW The maximum heating output
varies depending on the product.
Section "Technical data"
Automatic: Unit automatically
adjusts the maximum output to
the current system demand
Section
"Technical
data"
Adjustable
d.01 Pump overrun time in
heating mode
1 60 min 1 5 Adjustable
d.02 Maximum burner anti-
cycling time in heating
mode
2 60 min 1 20 Adjustable
d.04 Water temperature in
the cylinder
Current value Not
adjustable
d.05 Determined target
heating flow temper-
ature
Current value
Not
adjustable
d.06 Target domestic hot
water temperature
Current value (Combi boiler only) Not
adjustable
d.07 Target temperature for
the domestic hot water
cylinder
Current value Not
adjustable
d.08 Status of the 230 V
thermostat
Current value 0 = Room thermostat open (no
heat requirement)
1 = Room thermostat closed
(heat requirement)
Not
adjustable
d.09 Target heating flow
temperature that is
set on the eBUS room
thermostat
Current value Not
adjustable
d.10 Status of the internal
pump in the heating
circuit
Current value off / on Not
adjustable
d.11 Status of the heating
circuit's shunt pump
Current value off / on Not
adjustable
d.13 Status of the domestic
hot water circuit's cir-
culation pump
Current value off / on Not
adjustable
d.14 Operating mode of the
modulating pump
0 5 0 = variable rotational speed
(auto)
1; 2; 3; 4; 5 = Fixed rotational
speeds Section "Setting the
pump output"
0 Adjustable
d.15 Pump speed Current value % Not
adjustable
d.16 Status of the 24 V
room thermostat
Current value off = Heating off
on = Heating on
Not
adjustable
d.17 Heating control off = Flow temperature
on = Return temperature (ad-
justment for underfloor heating.
If you have activated the return
temperature control, the auto-
matic heating output determina-
tion function is not active.)
0 Adjustable