Appendix
0020300876_01 Energy
7
Installation and maintenance instructions 49
Dia-
gnostics
code
Parameter
Values
Unit Increment, select, explanation
Default set-
ting
Own setting
Min. Max.
d.77 Max. cylinder post-
heating
kW 1
Section "Technical data"
Adjustable
d.80 Running time in heat-
ing mode
Current value h Running time = Display value x
100
Not
adjustable
d.81 Running time in do-
mestic hot water mode
Current value h Running time = Display value x
100
Not
adjustable
d.82 Number of burner igni-
tions in heating mode
Current value Number of ignitions = Display
value x 100
Not
adjustable
d.83 Number of burner ig-
nitions in domestic hot
water mode
Current value Number of ignitions = Display
value x 100
Not
adjustable
d.84 Maintenance in 0 3000 h Number of hours = Display value
x 10
300 Not
adjustable
d.85 Increase in the min.
output (heating and
domestic hot water
mode)
kW 1 Adjustable
d.88 Flow rate limit value
for ignition in domestic
hot water mode
0 1 0 = 1.7 l/min (no delay)
1 = 3.7 l/min (2 s delay)
0 Adjustable
d.90 Status of the eBUS
room thermostat
Current value off = Not connected
on = Connected
Not
adjustable
d.91 Status DCF77 Current value Not
adjustable
d.93 Setting the product
code
0 99 1
The Device Specific Number
(DSN) can be found on the data
plate.
Adjustable
d.94 Delete fault list 0 1 off = No
on = Yes
Adjustable
d.95 Software versions 1 = Main PCB
2 = Interface PCB
Adjustable
d.96 Default setting (reset) 0 = No
1 = Yes
Adjustable
D Status codes Overview
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Status code Meaning
Displays in heating mode
S.0 Heating mode: No requirement
S.01 Heating mode: Fan prerun
S.02 Heating mode: Pump prerun
S.03 Heating mode: Burner ignition
S.04 Heating mode: Burner on
S.05 Heating mode: Pump/fan overrun
S.06 Heating mode: Fan overrun
S.07 Heating mode: Pump overrun
S.08 Heating mode: Temporary shutdown after heating procedure
Displays in domestic hot water mode
S.10 Domestic hot water mode: Requirement
S.11 Domestic hot water mode: Fan prerun