WIRING DIAGRAMS:
17
BUSBUS
BUS BUS
D C B A
DP-GB2A
End of line
OFF
AP AP
Access panel 2
ON
1 2 3 4 5 6
SW1
Access panel 1
ON
1 2 3 4 5 6
SW1
AP AP
Access panel 3
ON
1 2 3 4 5 6
SW1
Access panel 4
ON
1 2 3 4 5 6
SW1
(1) (1)
(1) (1)
To the distributors (building floors)
Lock release
max
. 12 Vdc/270mA.
Lock release
max
. 12 Vdc/270mA.
Lock release
max
. 12 Vdc/270mA.
Lock release
max
. 12 Vdc/270mA.
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
Important: For AC lock releases or a second lock release, see diagram 'Connection of Golmar AC and DC lock releases' on p. 18.
(1)
(1)
(1)
(1)
(1)
Video door entry system with 4 access panels, DP-GB2A distributor for door panels and Golmar DC lock
release.
STAINLESS STEEL NEXA MODULAR GB2 VIDEO DOOR ENTRY SYSTEM KIT HOUSES
N L
CN
Mains
100~240Vac
BUS (M) BUS(PL)
FA- 2GB /A
L
or
or
oror

Other manuals for golmar GB2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the golmar GB2 and is the answer not in the manual?

golmar GB2 Specifications

General IconGeneral
Door releaseYes
Number of buttons1
Power Supply12 Vdc
ColorWhite
MaterialPlastic
MountingSurface
InstallationSurface

Related product manuals