SERVICE
Electronic Control
FUNCTION:
1. Remote receiving
2. Testing and forced running
3. Position set for indoor unit wind vane
4. LED displaying and alarm
5. ON or OFF timer
6. Protection for the compressor
7. Current protection
8. High temperature protection of indoor heat exchanger in
heating mode
9. Auto defrosting and heating recovery in heating mode
10. Anti-cold air in heating mode.
Input Voltage 208VAC - 230VAC 175VAC - 253VAC
Input Power Frequency 60 Hz
Ambient Temperature (°F) 11°F - 111°F (Cooling & Heating units)
(°C) -12°C - 44°C (Cooling & Heating units)
(°F) 66°F - 111°F (Cooling only units)
(°C) 19°C - 44°C (Cooling only units)
Indoor Fan normal working amp Less than 1A
Oudoor Fan normal working amp Less than 1.5A
4-Way valve normal working amps Less than 1A
Swing motor 12V DC
Compressor Single phase
Working amp less than 15A
ELECTRONIC CONTROL
50 Hz