EasyManuals Logo

Goodwe ET Series Quick Installation Guide

Goodwe ET Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
1
PV String Safety:
1. Ensure the component frames and the bracket system are securely grounded.
2. Connect the DC cables using the delivered PV connectors. The manufacturer shall not be
liable for equipment damage if other connectors are used.
3. Ensure the DC cables are connected tightly, securely, and correctly. Inappropriate wiring may
cause poor contacts or high impedances, and damage the inverter.
4. Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the
voltage should be under the max DC input voltage. The manufacturer shall not be liable for
the damage caused by reverse connection and extremely high voltage.
5. The PV strings cannot be grounded. Ensure the minimum insulation resistance of the
PV string to the ground meets the minimum insulation resistance requirements before
connecting the PV string to the inverter. R=Max. Input Voltage (V)/30mA.
6. The PV modules used with the inverter must have an IEC61730 class A rating.
General Disclaimer
Safety Disclaimer
Warning
The information in this quick installation guide is subject to change due to product updates
or other reasons. This guide cannot replace the product labels or the safety precautions in
the user manual unless otherwise specied. All descriptions here are for guidance only.
Before installations, read through the quick installation guide. For additional information,
please see the user manual.
All operations should be performed by trained and knowledgeable technicians who are
familiar with local standards and safety regulations.
Check the deliverables for correct model, complete contents, and intact appearance. Contact
the manufacturer if any damage is found or any component is missing.
Use insulating tools and wear personal protective equipment when operating the equipment
to ensure personal safety. Wear anti-static gloves, clothes, and wrist strip when touching
electronic components to protect the inverter from damage. The manufacturer shall not be
liable for any damage caused by static electricity.
Strictly follow the installation, operation, and conguration instructions in this guide and user
manual. The manufacturer shall not be liable for equipment damage or personal injury if you
do not follow the instructions. For more warranty details, please visit https://en.goodwe.com/
warranty.
01 Safety Precautions
Inverter Safety:
1. The voltage and frequency at the connecting point should meet the on-grid requirements.
2. Additional protective devices like circuit breakers or fuses are recommended on the AC side.
Specication of the protective device should be at least 1.25 times the rated AC output rated
current.
3. PE cable of the inverter must be connected rmly. When there are multiple inverters, make
sure that all the grounding points on the enclosures are equipotential bonding.
4. Do not start the BACK-UP function if there is no battery in the PV system. The manufacturer
shall not be liable for the risks caused by not following this rule.
5. Do not apply mechanical load to the terminals, otherwise the terminals can be damaged.

Other manuals for Goodwe ET Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe ET Series and is the answer not in the manual?

Goodwe ET Series Specifications

General IconGeneral
TypeHybrid Inverter
Number of MPPTs2
THDi<3%
Nominal AC Voltage230V
AC Voltage Range180V to 280V
Operating Temperature Range-25°C to 60°C
Communication InterfacesRS485, WiFi

Related product manuals