15 16
6 Technical Parameters
Model
>99.5%
Integrated
Integrated
Integrated(optional)
Integrated
Integrated
VDE-AR-N 4105, AS4777.2&.3, RD1699, G83/2, IEC62109-2, VDE0126-1-1+A1, EN50438
According to IEC62109-1&-2, AS3100
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3
Category Ⅱ
SUNCLIX / MC4 (optional)
50/60Hz; 230Vac
45~55Hz/55~65Hz; 180~270Vac
<1%
0.9 leading~0.9 lagging
Single Phase
Category Ⅲ
GW1500-SS
1800
450
12
21
1
1500
1650
8
18.5
97.0%
>96%
12
GW2000-SS
2300
500
125~450
125
15
21
1
1
2000
2000
10
18.5
97.0%
>96%
12
GW3000-SS
3200
500
18
23
2
3000
3000
15
26.5
97.0%
>96.5%
13
GW3600-SS
4200
580
20
30
2
3600
4000
16
37
97.8%
>97.4%
18
GW4000-SS
4600
580
125~550
125
20
30
2
1
4000
4400
22
37
97.8%
>97.4%
18
GW4600-SS
5400
580
20
30
2
4600
5100
25
43
97.8%
>97.4%
18
355*380*134mm 390*417*142mm
Model
*
*
DC input Data
Max. DC power(W)
Max. DC voltage (V)
MPPT voltage range (V)
Starting voltage (V)
Max. DC current (A)
DC overcurrent protection(A)
No. of DC connectors
No. of MPPTs
DC overvoltage category
DC connector
AC Output Data
Norminal AC power(W)
Max. AC power(W)
Max. AC current(A)
AC overcurrent protection(A)
Norminal AC output
AC output range
THDi
Power factor
Grid connection
AC overvoltage category
Efficiency
Max. efficiency
Euro efficiency
MPPT adaptation efficiency
Protection
Residual current monitoring unit
Anti-islanding protection
DC switch
AC over current protection
Insulation monitoring
Certifications&Standards
Grid regulation
Safety
EMC
General Data
Dimensions (WxHxD)
Weight (kg)
Mounting
Ambient temperature range
Relative humidity
Moisture location category
Max. operating altitude
Protection degree
Environment category
External environment pollution degree
Topology
Night power consumption(W)
Cooling
Noise emision(dB)
Display
Communication
Standard warranty(years)
DC input Data
Max. DC power(W)
Max. DC voltage (V)
MPPT voltage range (V)
Starting voltage (V)
Max. DC current (A)
DC overcurrent protection(A)
No. of DC connectors
No. of MPPTs
DC overvoltage category
DC connector
AC Output Data
Norminal AC power(W)
Max. AC power(W)
Max. AC current(A)
AC overcurrent protection(A)
Norminal AC output
AC output range
THDi
Power factor
Grid connection
AC overvoltage category
Wall Mounting
-25~60°C (>45°C derating)
0~95%
4K4H
2000m
IP65
Outdoor & indoor
Grade1、2、3
Transformerless
<1
Natural Convection
<25
4.0'' LCD
USB2.0;RS485 or WiFi
5/10/15/20/25(optional)
GW4600-DS
5400
15/15
21
4600
5100
25
43
GW4200-DS
4600
580
125~550
125
15/15
21
2
2(can parallel)
Category Ⅱ
SUNCLIX / MC4 (optional)
4200
4400
21
43
50/60Hz; 230Vac
45~55Hz/55~65Hz; 180~270Vac
<1.5%
0.9 Leading~0.9 Lagging
Single phase
Category Ⅲ
GW3600-DS
3800
10/10
21
3600
3600
18
35