Questions and Answers

  • P
    pricewesleySep 23, 2025
    What does IFan Fail mean on my Goodwe Inverter?
    • A
      andrea21Sep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • B
    becky81Aug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe SDT G2?
    • M
      mooretamiAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • Y
    ybrownAug 25, 2025
    What to do if my Goodwe Inverter displays 'Isolation Fail'?
    • L
      Lisa MitchellAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • R
    Robert WrightAug 27, 2025
    What does 'Vac Fail' mean on my Goodwe SDT G2 Inverter?
    • H
      hooverjohnAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • L
    Lisa FergusonAug 27, 2025
    What causes 'Fac Fail' on a Goodwe SDT G2 Inverter?
    • T
      terry61Aug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • V
    Victor TorresSep 14, 2025
    What does ARC Fault mean on a Goodwe SDT G2, and how do I fix it?
    • E
      Edwin RandallSep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • P
    petersonstacySep 12, 2025
    What should I do if my Goodwe Inverter displays a PV Over Voltage error?
    • S
      Sophia GrahamSep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • M
    Michael AndersonSep 13, 2025
    Why does my Goodwe SDT G2 show a Fac Fail error?
    • D
      Dr. Paula AllenSep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • M
    Mariah AdkinsSep 4, 2025
    What does 'IFan Fail' mean on my Goodwe SDT G2 Inverter?
    • L
      Lori PittmanSep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • D
    Daniel RodriguezSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe SDT G2?
    • L
      lbartonSep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

About This Manual

Applicable Models

Lists the inverters covered by this user manual.

Target Audience

Defines the intended professional readership for the manual.

Symbol Definitions

Explains the meaning of warning and notice symbols used.

Manual Updates

Notes that the manual content may be updated without prior notice.

Safety Precautions

General Safety Guidelines

Outlines universal safety rules for inverter installation and operation.

DC Side Safety

Covers crucial safety measures specific to the DC electrical side.

AC Side Safety

Details safety precautions for the AC electrical connection.

Inverter Installation Safety

Addresses safety considerations during the physical installation process.

Personnel Safety Requirements

Specifies the necessary qualifications and protective measures for personnel.

Product Introduction

Application Scenarios

Describes the typical usage environments and configurations of the inverter.

Supported Grid Types

Lists the various types of electrical grids the inverter can connect to.

Inverter Appearance Overview

Provides a general overview of the inverter's physical design and features.

Check and Storage

Pre-Receiving Inspection Procedures

Steps to verify product condition and model before accepting delivery.

Package Contents (Deliverables)

Details all items included in the inverter package.

Storage Environment Guidelines

Recommends conditions for safe storage of the inverter.

Installation

Installation Site Requirements

Specifies environmental and structural conditions for proper installation.

Inverter Installation Process

Outlines the steps and considerations for mounting and installing the inverter.

Electrical Connection

Electrical Connection Safety Precautions

Critical safety measures before and during electrical connections.

PE Cable Connection Procedure

Step-by-step guide for connecting the protective earth (PE) cable.

PV Input Cable Connection

Instructions for connecting the DC input cables from PV modules.

AC Output Cable Connection

Guidance on safely connecting the AC power output cable to the grid.

Communication Cable Connection

Procedures for connecting communication cables for system monitoring.

Equipment Commissioning

Pre-Commissioning Checklist

Essential checks to perform before powering on the equipment.

Inverter Power-On Procedure

Sequence for safely energizing the inverter and connecting to the grid.

System Commissioning

Indicator and Button Functions

Explains the meaning of LEDs and buttons on the inverter.

LCD Parameter Configuration

Guide for setting inverter parameters using the LCD interface.

App-Based Parameter Configuration

Instructions for configuring the inverter via a mobile application.

Maintenance

Inverter Power-Off Procedure

Steps to safely disconnect power from the inverter for maintenance.

Inverter Removal Procedure

Instructions for safely detaching and removing the inverter.

Inverter Disposal Guidelines

Information on environmentally sound disposal of the inverter.

Troubleshooting Faults

Advice on diagnosing and resolving common inverter issues.

Goodwe SDT G2 Series Specifications

General IconGeneral
Number of MPPT2
AC Frequency50/60 Hz
DC SwitchYes
Protection DegreeIP65
Nominal AC Voltage230V
CommunicationRS485
Operating Temperature Range-25°C to 60°C
ModelSDT G2 Series

Related product manuals