The stove of NB-P15'S air input pipe diameter is 40X80 mm, venting pipe diameter is 76
mm. The total length of pipes is no longer than 3m and elbows are not available. Indoor
venting pipe joint should be sealed by silicone sealant to prevent exhaust leaking into the
room. Venting pipe and termination should be waterproof and avoid being blocked. Or, the
stove can not work properly. When the installation is limited by space or the owner‘s special
requirements and the pipes‘ length should be longer than 3m and need elbows, the diameters
of the air input pipe and venting pipe must be increased properly for smooth convection. If
not, it will influence the burning and the stove can not work properly. The owner should
connect with the local seller for the right installation. When pellet stove is normal working,
the temperature on venting pipe surface can reach 200˚C, so the combustible things, clothes
and furniture should be away from the venting pipe. To prevent scald, don‘t touch the heating
surface!