locking system and sealed with high temperature silicone.
The pipe should be siliconed and fastened with three screws to the stove‘s flue collar.
The longer the run of pipe and the more elbows used, the greater the resistance to the flow of flue
gases. Four inch diameter pellet pipe is recommended for pipe runs greater than 15 feet or when a
number of elbows are used.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYS TEM OF
THIS UNIT. FO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
Here are some examples of installation in different situation
Horizontal installations that terminate without any vertical sections of pipe are approved;
However, wind may direct flue gases towed the house causing discoloring problems. For this
reason, horizontal and up 5 feet or horizontal and through the eave installations are recommended.
To aid in cleaning, wherever possible, the venting system should include a tee with clean out
attached to the flue collar on the stove.
Masonry Chimney
When venting into a masonry chimney, the pellet pipe can terminate just inside the chimney
.However, it is recommended to run the pellet pipe to the top of the chimney.
Fireplace
When venting into a fireplace chimney, the pellet pipe can terminate just above the damper.
However, it is recommended to run the pellet pipe to the top of the chimney.
Vertical
If the length of pipe exceeds 15 feet, 4 inch pipe rather than 3 inch vent pipe should be used.