7. Troubleshooting
The control panel of the stove has trouble examine sensors. When the sensor detect the
abnormal work temperature (below 30˚C), or the other sensors temperature is above 70˚C the
auto-control temperature switches will react accordingly. When temperature is below 30˚C,
the safety control system will stop the stove automatically; when the other sensor, fixed into
the hopper, detect the temperature is above 70˚C, the stove will be shut down.
The general troubles, the possible reasons and the solutions are as following, after solving
problems, start the stove again:
problems
reason
solution
1. The start light does not
light when power is on
No power in stove or in the
control panel.
Check the power and wires.
2. The blower doesn‘t
work after pressing the
start bottom.
If after 15 mins, it doest
work, there must be
wrong
It is normal.
It will start automatically
when the temperature is
above 30 degrees on the
venting pipe.
Please wait
No power in stove or in the
control panel.
Or Unplugged on the mother
board
The low temperature sensor is
broken
Check the power and wires.
Plug it
Replace it
3. No feeding after 20 seconds of starting.