venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs
during start up, shutdown, or incorrect operation of the room heater will lead to some soot
formation which will collect in the exhaust venting system. The exhaust venting system should be
inspected at least once every year to determine if cleaning is necessary. Sweep the pipe as needed.
A tee and the cleanout in the vent system attached to the stove‘s flue collar will facilitate this
cleaning.
Required Cleaning Schedule after Number of Bags Burned
Burn Pot=10 bags
Ash Drawer=50 bags
Flue Fan=100 bags
Blower=100 bags
NOTE: Cleaning schedule will vary depending on quality of pellets used. Burned high ash
pellets used. Burned high ash pellets will require more frequent cleaning
CHANGE THE HEAT RESISTOR EVERY TWO OR THREE MONTHS
Normally, we have a spare set off heat resistor with a new stove!