Check the air intake pipe and
venting pipe blocked or not, and
clean it. Change to the big diameter
pipes if pipes are too long to affect
combustion.
Adjust the combustion fan's speed
up
Call the dealer to reset the program
7 The fire put out and
power is off
automatically.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30˚C) is wrong.
Set temperature is
reached
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30˚C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again
8 The blower still works
after the stove is cool and
fuel feed stops.
The low temperature
switch (30˚C) is broken.
Unqualified fuel
Blower speed is too high.
Heat exchange tubes are
dirty.
Use the standard specially pellet.
Use higher power
Clean the heat exchange tubes.
10. Showing "Pressure
Erro" on the display
Vent pipe is blocked
The door is opening
The are some leakages
Shut down the stove, check the
venting pipe
Close the door and unplugged then
restart
Check it and repair it.